Walker Industrial: Home > Manufacturers > P - S > SSAC > Timers & Flashers > Timers > Dedicated > TA Series

TA Series
Sort By:
1
TA12D1 - SSAC TA12D1 - SSAC Timer HVAC Lockout 12VDC 1A FXD 1m 2x2

Timer HVAC Lockout 12VDC 1A FXD 1m 2x2 (SSAC TA12D1)

Usually Ships in 3 to 5 Days
Price: $54.93
Free Shipping
TA12D2 - SSAC TA12D2 - SSAC Timer HVAC Lockout 12VDC 1A FXD 2m 2x2

Timer HVAC Lockout 12VDC 1A FXD 2m 2x2 (SSAC TA12D2)

Usually Ships in 3 to 5 Days
Price: $54.93
Free Shipping
TA24A0.5 - SSAC TA24A0.5 - SSAC Timer HVAC Lockout 24VAC 1A FXD 0.5m 2x2

Timer HVAC Lockout 24VAC 1A FXD 0.5m 2x2 (SSAC TA24A0.5)

Usually Ships in 3 to 5 Days
Price: $54.93
Free Shipping
TA24A3 - SSAC TA24A3 - SSAC Timer HVAC Lockout 24VAC 1A FXD 3m 2x2

Timer HVAC Lockout 24VAC 1A FXD 3m 2x2 (SSAC TA24A3)

Usually Ships in 3 to 5 Days
Price: $54.93
Free Shipping
TA24A5 - SSAC TA24A5 - SSAC Timer HVAC Lockout 24VAC 1A FXD 5m 2x2

Timer HVAC Lockout 24VAC 1A FXD 5m 2x2 (SSAC TA24A5)

Usually Ships in 3 to 5 Days
Price: $54.93
Free Shipping
   
 
1
TA Series

The TA Series prevents rapid recycling of a compressor. A lockout delay is started when the thermostat opens, or input voltage is lost. Eliminates tripped circuit breakers or blown fuses caused by a locked rotor during short cycling. The TA will not allow the compressor to start when the line voltage is low. Chatter of the compressor relay is eliminated. Because of the fast initiate time, bounce of the thermostat will not be transmitted to the compressor relay coil. A 30 second delay provides anti-reversing protection for scroll compressors.

Operation (Lockout):
On initial closure of the S1, the compressor relay energizes immediately. When S1 opens or input voltage is interrupted, a lockout time delay is initiated. During this lockout time delay, the compressor relay cannot be energized. The low voltage (brownout) protection prevents energization of the compressor when the line voltage is low.
Reset: The lockout time delay cannot be reset. After the time delay is completed, the unit automatically resets.

Features:

  • Ideal for HVAC/R applications
  • Lockout delay prevents rapid recycling of a compressor
  • Low voltage brownout protection
  • Circuitry to activate the cooling anticipator (24VAC models)
  • Eliminates nuisance service calls due to blown fuse or tripped breakers

Auxiliary Products:

  • Female quick connect: P/N: P1015-64 (AWG 14/16)
  • Mounting bracket: P/N: P1023-6
  • Quick connect to screw adaptor: P/N: P1015-18
  • DIN rail: P/N: C103PM (Al)
  • DIN rail adaptor: P/N: P1023-20