SLR Series
The SLR Series has no isolation between the control switch input and the solid-state output. Select the SLR for applications where the control switch is the same voltage source as the load. Provides the noiseless, reliability and long life of a solid-state relay, without the cost of isolation circuitry. Zero voltage switching SLR2 can extend the life of an incandescent lamp up to 10 times its normal life. Random switching SLR1 is normally used for inductive loads. When fully insulated female terminals are used on the connection wires, the system meets the requirements for touch-proof connections.
Operation
The solid-state output is located between terminals 1 and 2 and can be ordered as either normally open or normally closed, when voltage is applied and S1 is open. When S1 is closed, the solid-state output between terminals 1 and 2 closes (or opens). If S1 is opened, the solid-state output will open (or close).
Reset: Opening S1 resets the output to its original state. Reset is also accomplished by removing input voltage.
Features:
- SLR1 - Random switching for inductive loads
- SLR2 - Zero voltage switching for resistive & incandescent loads
- Normally open or normally closed output
- 1 - 20A with up to 200A inrush
- 0.25 in. (6.35 mm) termination with single
hole mounting
- Noiseless switching, reliability, and long life
Auxiliary Products:
- Quick connect to screw adaptor:
P/N: P1015-18
- Female quick connect:
- P/N: P1015-13 (AWG 10/12)
- P/N: P1015-64 (AWG 14/16)
- P/N: P1015-14 (AWG 18/22)
|
|
|