INT-03-024 - Edwards Signaling INT-03-024, SAFETY MONITOR REL
The
INT-03-024 or INT-03-120, Safety Monitor Relay is intended for use as a
part of a safety circuit in guard interlock applications. It is a
safety relay which used positive-guided relays, configured for
self-checking, to inhibit machine start-up in the event of an internal
component failure.
Both normally-open and normally-closed inputs
are required. Multiple N.O. contacts can be wired in series while
multiple N.C. contacts can be wired in parallel. Upon failure of either
the N.O. or N.C. contact, the relay will prevent restart.
The INT-03 relay can also monitor contacts on external relays for controlling expansion block relays (INT-05 and INT-06).
Applications - Meets European Machine Safety Standards, Risk Category 4
- Designed for use with 300-BT Series GuardSwitch
- Requires both normally-open and normally-closed inputs
- Inhibits machine restart in case of component failure
- Provides 2 safe outputs plus a form C output for signaling
- Low current for longer GuardSwitch life
- DIN Rail or panel mount
- LED power on indicator
Download the INT-03-024 specification sheet in *.pdf format
Specifications
Control Inputs (X1, X2 & Y1, Y2 terminals) Open-circuit voltage = 24VDC Closed-circuit current = 24mA Max.contact resistance = 30 Ohms Simultaneity = 500 ms typical
Safe Outputs (A,B/C,D terminals) Voltage = 230 VAC/60VDC Current = 4A (resistive) Response time = < 100 ms Fuse = 4A, 250V, 5 x 20 mm, F/T
AUX. Signaling Outputs (E,F,G terminals) Voltage = 120 VAC/30VDC Current = 1A (resistive) ----------------------------------------------------------------------------------------------------------------------- Note: Transient protection is required across the load when switching an inductive load.
Operation A. With a RESTART button from Terminal 1 to 2, INT-03 energizes after all guards are in place and RESET button is pressed (monitored contacts must also be closed). B. With a jumper from Terminal 1 to 2, INT-03 energizes when all guards are in place (autostart). C. With no connection from Terminal 1 or 2, INT-03 will not energize.
|
|
|
|
|
|
|