Module connects to two sensors with PNP outputs, monitoring rotation
(rpm) or linear movement. Provides over-speed, under-speed and
zero-speed detection.
- Feedback input monitors external machine control elements
- 24V ac/dc operation
- Two redundant, forced guided output contacts rated at 4A, plus one auxiliary N.C. output contact
- Stop Category 0, per ISO 13850 (EN 418), IEC 60204-1, and ANSI NFPA
79; Category 3, SIL Claimed Level (SIL CL) 3 to EN 62061, Category 3 /
Performance Level (PL) e to DIN EN ISO 13849-1
- DIN-rail mountable 45 mm wide housing with removable terminal blocks
- Energizes output relays (closes N.O. contacts), when speed drops below set value, for "standstill" (under-speed) monitoring
- De-energizes output relays (opens N.O. contacts), when speed rises above set value, for over-speed monitoring
|