Across the Line & Combination Starters
|
|
|
|
Across the Line Starters Description A9 - AF750
- Maximum UL horsepower ratings
- UL508A Panel Program, #E105450
- NEMA sizes (00 – 7) available
- Compact space-saving design
- Standard auxiliary contact configurations:
- A9 - A40 1 NO
- A50 - AF750 1 NO & 1 NC
- Additional auxiliary contact blocks are available
- Consult factory for DC ratings & DC control operation
- Fast, snap-on DIN rail mounting (A9 - A110)
- Double break contact design
- Snap-on front and side mounted accessories include mechanical latch, pneumatic timer and 1 & 4 pole auxiliary contact blocks (A9 - A110)
- Easy coil change
- Captive terminal screws
- NEMA, UL, CSA, and most other international standards
- cUL marked
- Operates over an extended voltage range of 85% to 110% of rated control voltage
- Screwdriver guide holes
For reduced voltage starters, consult factory.
Enclosure types
- NEMA 1 (Indoor metal)
- NEMA 3R (Outdoor metal)
- NEMA 12 (Metal dusttight)
- NEMA 4X (Stainless steel)
- NEMA 4 (Water tight)
- NEMA 1, 3R, 4, 4X, & 12 (Plastic)
- IP 65 plastic A9 – A16 starters
- NEMA 7 & 9
- Class I, Group C, D, Div 1 & 2
- Class II, Groups E, F, & G, D iv 1 & 2
- Class III, 4X
Overload relay protection Starters, sizes A9 – A300, have Class 10 adjustable thermal bimetallic overload relay protection as standard.
Sizes AF400 – AF750, have selectable Class 10, 20, 30 adjustable electronic overload relay protection as standard.
Electronic overload relay protection is available for other starter sizes.
Combination Starters Description A9 – AF750
- Maximum UL/CSA horsepower ratings
- Available with ABB non-fusible or fusible disconnect switches and MCP, thermal magnetic or electronic trip type circuit breakers
- Compact space saving design
- Standard auxiliary contact configurations:
- A9 – A40 1 N.O.
- A50 – AF750 1 N.O. & 1 N.C.
- Double break contact design
- Lowest possible contact bounce
- Early make & late break auxiliary contacts available
- Operates over an extended voltage range of 85% to 110% of rated control voltage
- UL listed
For reduced voltage starters, consult factory.
Overload relay protection Starters, sizes A9 – A185, have Class 10 adjustable thermal bimetallic overload relay protection as standard.
Sizes AF400 – AF750, have selectable Class 10, 20, 30 adjustable electronic overload relay protection as standard.
Electronic overload relay protection is available for other starter sizes.
Download the Across the Line & Combination Starters brochure in *.pdf format Download the Starters index in *.pdf format
|
|
|