Home > Manufacturers > P - S > Schmersal > Solenoid-Latching Interlocks > AZM400 Solenoid-Latching Interlocks >

A-K8P-M12-S-G-10M-BK-2-X-A-4 - A-K8P-M12-S-G-10M-BK-2-X-A-4 10M M12 Cable for AZM400 Series ( 103007359 )

A-K8P-M12-S-G-10M-BK-2-X-A-4 - Schmersal
AZM400Z-ST-1P2P
 
Price: $125.00
Manufacturer SKU: A-K8P-M12-S-G-10M-BK-2-X-A-4
Manufacturer ID: 103007359


Free Shipping
Availability: Usually Ships in 3 to 5 Days
Part Number: A-K8P-M12-S-G-10M-BK-2-X-A-4
Qty:

Description
 
*Note: This is only the connecting cable. Solenoids, actuators, and accessories are sold separately.*

Specifications:
A-K8P-M12-S-G-10M-BK-2-X-A-4:
• 10 m
• Pre-wired cable
• 8-pole

The AZM400 is a safety rated motorized bolt lock with an integrated RFID based electronic safety sensor.

Operating Principle:
The Aluminum die-cast body contains the RFID sensor and a motor-driven locking bolt, which fits into the hole of the actuator block with the matching RFID target. Once locked, the solenoid bolt provides a locking force of 10,000 N. The motorized AZM400 is a bi-stable system, thus in the event of a power failure the switch maintains the last locked status of the interlock.

In addition, the AZM400 uses RFID to detect the actuator and indicate a closed guard. This non-contact operating principle limits wear on components, tolerates misalignment, and offers the option of individual coding.

Intelligent Locking:
The AZM400 can detect if the locking bolt has been blocked from reaching a "locked" state. Before reporting a fault the switch will make a second autonomous attempt at locking, therefore reducing the number of error messages and protecting the device and machine from damage.

Safety Classification:
The AZM400 series is compliant with North American and International standards such as cULus and CE. Its two-channel input signal meets PLe/Category 5 (ISO 13849) or SIL3 (IEC 61508) for both its interlock and guard locking function. It is a Type 4 interlock per ISO 14119, with a high coding level with the individual coding option (I1 or I2).

Available Features and Options:
  • Visual diagnostics via 3 LEDs
  • 1 or 2 auxiliary outputs for enhanced diagnostics
  • M12 connector
  • Manual override or emergency release knob for bolt retraction
  • Electronic release via auxiliary power supply
  • Individual coding options:
  • I1: One time teaching process
  • I2: Re-teaching possible, 10 minute delay